OligoArrayDb, the Source of Microarray Probes for
Streptococcus thermophilus LMG 18311
Probe set created on 2009-11-13, updated on 2009-11-13.
(Go directly to the oligonucleotide page)
[HOME]

[Source of Commercial Oligonucleotide Microarrays for Streptococcus thermophilus LMG 18311]


The Streptococcus thermophilus LMG 18311 genome is provided in 1 piece of sequence ( CP000023 ) representing a total of 1889 transcripts. These sequences have been analized for their GC content as this is an important parameter for probe design. The average GC content of these coding sequences is 39%, with a minimum and a maximum of 24% and 48% respectively. Ninety percent of these sequences have a GC content comprised between 32%and 44%. These values have been used to set OligoArray options during design. Here is the parameter set used for this particular design.

This database contains 5194 oligonucleotides to represent the Streptococcus thermophilus LMG 18311 transcriptome. Among these 5194 oligonucleotides, 4835 are considered to be fully specific to their targets according to the design parameters described above.  In other terms, this database provides oligonucleotides for 1871 transcripts and 1758 (93% of all sequences) have at least one specific oligo representing them. The figure below gives details on the number of CDS with specific probes.

Understanding this graph:
In the best case, you want the proportion of black and red genes to be as small as possible. Black ones are the genes with no probe at all. These genes will always be missing on your array. Red ones are the sequences for which OligoArray was not able to find a specific probes. However, it reported a non-specific probe. Our thresholds to define specific probes are quite conservative and many non-specific probes will actually prove to be specific in a real experiment. All other genes (blue, yellow and green) have at least one specific probe. While the number of genes with 3 specific probes may vary greatly from an organism to another, this may have little effect on your microarray design. Indeed, many will prefer to have one probe per gene, this probe being replicated several times on the array rather than having several probes per gene with less replicates.


Here we report the transcripts that do not have any oligonucleotide at all or any specific oligonucleotides.

With all these data in mind, you may want to access to the oligonucleotide page where you can download a microarray probe set representing the coding sequences of Streptococcus thermophilus LMG 18311.
 

[OligoArrayDb Home Page]