OligoArrayDb, the Source of Microarray Probes for
Mesorhizobium loti MAFF303099
Probe set created on 2009-11-13, updated on 2009-11-13.
(Go directly to the oligonucleotide page)
[HOME]

[Source of Commercial Oligonucleotide Microarrays for Mesorhizobium loti MAFF303099]


The Mesorhizobium loti MAFF303099 genome is provided in 3 pieces of sequence ( AP003017, BA000012, BA000013 ) representing a total of 7281 transcripts. These sequences have been analized for their GC content as this is an important parameter for probe design. The average GC content of these coding sequences is 62%, with a minimum and a maximum of 0% and 74% respectively. Ninety percent of these sequences have a GC content comprised between 55%and 67%. These values have been used to set OligoArray options during design. Here is the parameter set used for this particular design.

This database contains 20450 oligonucleotides to represent the Mesorhizobium loti MAFF303099 transcriptome. Among these 20450 oligonucleotides, 17015 are considered to be fully specific to their targets according to the design parameters described above.  In other terms, this database provides oligonucleotides for 7231 transcripts and 6624 (90% of all sequences) have at least one specific oligo representing them. The figure below gives details on the number of CDS with specific probes.

Understanding this graph:
In the best case, you want the proportion of black and red genes to be as small as possible. Black ones are the genes with no probe at all. These genes will always be missing on your array. Red ones are the sequences for which OligoArray was not able to find a specific probes. However, it reported a non-specific probe. Our thresholds to define specific probes are quite conservative and many non-specific probes will actually prove to be specific in a real experiment. All other genes (blue, yellow and green) have at least one specific probe. While the number of genes with 3 specific probes may vary greatly from an organism to another, this may have little effect on your microarray design. Indeed, many will prefer to have one probe per gene, this probe being replicated several times on the array rather than having several probes per gene with less replicates.


Here we report the transcripts that do not have any oligonucleotide at all or any specific oligonucleotides.

With all these data in mind, you may want to access to the oligonucleotide page where you can download a microarray probe set representing the coding sequences of Mesorhizobium loti MAFF303099.
 

[OligoArrayDb Home Page]